Question 1 of 6
Basic
The TPE3’s integrated heat energy meter ensures that:
Question 2 of 6
Basic
How many external pressure sensors are needed in the pipe system when three TPE3s are installed?
Question 3 of 6
Basic
The TPE3’s flow limit function eliminates the need for what?
Question 4 of 6
Basic
The TPE2 features a limit-exceeded function. What does this do?
Question 5 of 6
Basic
The TPE3 has unique wireless technology that allows a number of pumps installed in parallel to connect directly to each other. How many pumps can be installed in parallel?
Question 6 of 6
Basic
A traditional chilled water system is often constructed with primary and secondary loops with constant flow in the primary loop. Which alternative construction does Grundfos recommend?
Question 6 of 6
Basic
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 6 - Groundbreaking vertical In-line pump (TPE3)
Sorry. You did not pass the 6 - Groundbreaking vertical In-line pump (TPE3) test this time
Achieved badges:
How would you rate this course?
1: The TPE3’s integrated heat energy meter ensures that:
Energy consumption will not exceed what is expected
You can find the answer here >
1: The TPE3’s integrated heat energy meter ensures that:
Energy consumption in all parts of the system is equal
You can find the answer here >
1: The TPE3’s integrated heat energy meter ensures that:
Energy consumption in HVAC systems is monitored more efficiently
2: How many external pressure sensors are needed in the pipe system when three TPE3s are installed?
0
2: How many external pressure sensors are needed in the pipe system when three TPE3s are installed?
2: How many external pressure sensors are needed in the pipe system when three TPE3s are installed?
3: The TPE3’s flow limit function eliminates the need for what?
Pump throttling valve
3: The TPE3’s flow limit function eliminates the need for what?
All throttling and balancing valves in the system
You can find the answer here >
3: The TPE3’s flow limit function eliminates the need for what?
Control valves in the system
You can find the answer here >
4: The TPE2 features a limit-exceeded function. What does this do?
The limit-exceed function allows the pump to stop when the system is approaching a given temperature limit
You can find the answer here >
4: The TPE2 features a limit-exceeded function. What does this do?
The limit-exceed function allows to influence pump operation, when for example a given pressure or temperature limit is exceeded.
4: The TPE2 features a limit-exceeded function. What does this do?
The limit-exceed function allows the pump to start when the system is approaching a given temperature limit
You can find the answer here >
5: The TPE3 has unique wireless technology that allows a number of pumps installed in parallel to connect directly to each other. How many pumps can be installed in parallel?
5: The TPE3 has unique wireless technology that allows a number of pumps installed in parallel to connect directly to each other. How many pumps can be installed in parallel?
4
5: The TPE3 has unique wireless technology that allows a number of pumps installed in parallel to connect directly to each other. How many pumps can be installed in parallel?
6: A traditional chilled water system is often constructed with primary and secondary loops with constant flow in the primary loop. Which alternative construction does Grundfos recommend?
We recommend a system with only a primary loop and variable flow
6: A traditional chilled water system is often constructed with primary and secondary loops with constant flow in the primary loop. Which alternative construction does Grundfos recommend?
We recommend primary only systems with constant flow
You can find the answer here >
6: A traditional chilled water system is often constructed with primary and secondary loops with constant flow in the primary loop. Which alternative construction does Grundfos recommend?
We recommend primary/secondary systems with constant flow in both loops
You can find the answer here >