- Grundfos United Kingdom
- Learn
- Ecademy
- All courses
- 7 - Chilled water systems f...
- Test your knowledge
Question 1 of 6
Intermediate
What is FLOWLIMIT?
Question 2 of 6
Intermediate
What affects a system’s total cost of ownership the most?
Question 3 of 6
Intermediate
Which of the following statements about VPF systems is true?
Question 4 of 6
Intermediate
How does the VPF design achieve energy and cost savings?
Question 5 of 6
Intermediate
By separating pump control from chiller design, what does the VPF design achieve?
Question 6 of 6
Intermediate
If the chilled water temperature range for which the system is designed is not maintained…
Question 6 of 6
Intermediate
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 7 - Chilled water systems for air conditioning
Sorry. You did not pass the 7 - Chilled water systems for air conditioning test this time
Achieved badges:
How would you rate this course?
1: What is FLOWLIMIT?
An external flow commissioning algorithm available from an app
You can find the answer here >
1: What is FLOWLIMIT?
An intelligent control valve placed after the pump
You can find the answer here >
1: What is FLOWLIMIT?
An electronic flow commissioning functionality built into the pump
2: What affects a system’s total cost of ownership the most?
Investing to increase user comfort
You can find the answer here >
2: What affects a system’s total cost of ownership the most?
Low Delta T syndrome
2: What affects a system’s total cost of ownership the most?
Low flow in the system
You can find the answer here >
3: Which of the following statements about VPF systems is true?
They are getting cheaper in installation and more energy efficient
3: Which of the following statements about VPF systems is true?
They offer substantial energy savings, but are expensive compared to other system alternatives (like primary secondary)
You can find the answer here >
3: Which of the following statements about VPF systems is true?
They need more space in buildings or facilities compared to other system alternatives
You can find the answer here >
4: How does the VPF design achieve energy and cost savings?
By keeping constant-flow chiller pumps in a separate system
You can find the answer here >
4: How does the VPF design achieve energy and cost savings?
By eliminating the constant-flow chilled water pumps by variable-flow
4: How does the VPF design achieve energy and cost savings?
It doesn’t – but reliability is greatly increased
You can find the answer here >
5: By separating pump control from chiller design, what does the VPF design achieve?
Ensures the pumps keep the water sufficiently cold to satisfy the building load
You can find the answer here >
5: By separating pump control from chiller design, what does the VPF design achieve?
A chiller and its primary pump typically operate in tandem
You can find the answer here >
5: By separating pump control from chiller design, what does the VPF design achieve?
The pumps maintain a target differential pressure, Delta P, at a specific point in the system
6: If the chilled water temperature range for which the system is designed is not maintained…
… you risk low Delta T syndrome
6: If the chilled water temperature range for which the system is designed is not maintained…
…you need to install new control valves
You can find the answer here >
6: If the chilled water temperature range for which the system is designed is not maintained…
…you need to increase flow through the chillers
You can find the answer here >