Question 1 of 6
Advanced

Which type of output filter does Grundfos recommend?

Question 2 of 6
Advanced

The larger the cross-sectional area of the cable, the lower the energy losses. True or false?

Question 3 of 6
Advanced

What is the main advantage of using a variable frequency drive in submersible pumps?

Question 4 of 6
Advanced

When does undervoltage typically happen?

Question 5 of 6
Advanced

Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?

Question 6 of 6
Advanced

At which stage does Grundfos recommend installing an output filter?

Question 6 of 6
Advanced

Happy with your answers?

Submit your current answers and get the final test result.

Test results

Congratulations. You have passed the test and completed the 26 - The SP submersible pump
Sorry. You did not pass the 26 - The SP submersible pump test this time
Achieved badges:
How would you rate this course?
1: Which type of output filter does Grundfos recommend?
1: Which type of output filter does Grundfos recommend?
Sine wave filter
1: Which type of output filter does Grundfos recommend?
2: The larger the cross-sectional area of the cable, the lower the energy losses. True or false?
True
2: The larger the cross-sectional area of the cable, the lower the energy losses. True or false?
3: What is the main advantage of using a variable frequency drive in submersible pumps?
It allows you to regulate your installation
3: What is the main advantage of using a variable frequency drive in submersible pumps?
3: What is the main advantage of using a variable frequency drive in submersible pumps?
It is easy to install
You can find the answer here >
4: When does undervoltage typically happen?
When the drop cables are too small
4: When does undervoltage typically happen?
When the drop cables are too large
You can find the answer here >
4: When does undervoltage typically happen?
When there is too much heat in the motor
You can find the answer here >
5: Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?
5: Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?
5: Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?
Motor power
6: At which stage does Grundfos recommend installing an output filter?
If the net supply is over 340 V
You can find the answer here >
6: At which stage does Grundfos recommend installing an output filter?
If the net supply is over 360 V
You can find the answer here >
6: At which stage does Grundfos recommend installing an output filter?
If the net supply is over 380 V