- Grundfos Albania
- Learn
- Ecademy
- All courses
- 3 - Wastewater
- Test your knowledge
Question 1 of 8
Intermediate
Which method of backflow prevention has the following disadvantages: Highly sensitive to sand and solid objects in the water. In a backflow situation, it is not possible to use the sanitary facilities that are connected to this device. Storm water drains cannot be connected to this device. The device is not 100% safe and should be used only to protect secondary rooms with no vital technical installations.
Question 2 of 8
Intermediate
What is grey wastewater?
Question 3 of 8
Intermediate
Under which circumstances should you consider a pressurised wastewater system rather than a gravitation system
Question 4 of 8
Intermediate
Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection. Ideal for safeguarding electrical and other high value equipment. Offers unlimited use of sanitary facilities in case of backflow. Is easily serviced. Can be installed in a building’s storm water drains. Is not sensitive to sand and solid objects in the water.
Question 5 of 8
Intermediate
What are the disadvantages of the traditional gravitation system?
Question 6 of 8
Intermediate
Why is the life cycle cost of the pressurised wastewater system low?
Question 7 of 8
Intermediate
Who has the financial responsibility in the case of flooding in most countries?
Question 8 of 8
Intermediate
What are the four most common types of wastewater from commercial buildings?
Question 8 of 8
Intermediate
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 3 - Wastewater
Sorry. You did not pass the 3 - Wastewater test this time
Achieved badges:
How would you rate this course?
1: Which method of backflow prevention has the following disadvantages: Highly sensitive to sand and solid objects in the water. In a backflow situation, it is not possible to use the sanitary facilities that are connected to this device. Storm water drains cannot be connected to this device. The device is not 100% safe and should be used only to protect secondary rooms with no vital technical installations.
Anti-flooding valves
1: Which method of backflow prevention has the following disadvantages: Highly sensitive to sand and solid objects in the water. In a backflow situation, it is not possible to use the sanitary facilities that are connected to this device. Storm water drains cannot be connected to this device. The device is not 100% safe and should be used only to protect secondary rooms with no vital technical installations.
Pumping stations
You can find the answer here >
1: Which method of backflow prevention has the following disadvantages: Highly sensitive to sand and solid objects in the water. In a backflow situation, it is not possible to use the sanitary facilities that are connected to this device. Storm water drains cannot be connected to this device. The device is not 100% safe and should be used only to protect secondary rooms with no vital technical installations.
Lifting stations
You can find the answer here >
2: What is grey wastewater?
Water, which is discharged from showers, sinks, washing machines, canteen kitchens etc.
2: What is grey wastewater?
Water which is primarily discharged from toilets
You can find the answer here >
2: What is grey wastewater?
Water which has not been affected by human influence
You can find the answer here >
3: Under which circumstances should you consider a pressurised wastewater system rather than a gravitation system
When there is a long distance between the building and the sewer main, when the sewer main is up-hill or when there are obstacles between the building and the sewer main.
3: Under which circumstances should you consider a pressurised wastewater system rather than a gravitation system
When there is a long distance between the building and the sewer main or when the sewer main is located far below the building.
You can find the answer here >
3: Under which circumstances should you consider a pressurised wastewater system rather than a gravitation system
When there is a short distance between the building and the sewer main or there are obstacles between the building and sewer main.
You can find the answer here >
4: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection. Ideal for safeguarding electrical and other high value equipment. Offers unlimited use of sanitary facilities in case of backflow. Is easily serviced. Can be installed in a building’s storm water drains. Is not sensitive to sand and solid objects in the water.
Anti-flooding valves
You can find the answer here >
4: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection. Ideal for safeguarding electrical and other high value equipment. Offers unlimited use of sanitary facilities in case of backflow. Is easily serviced. Can be installed in a building’s storm water drains. Is not sensitive to sand and solid objects in the water.
Pumping stations
You can find the answer here >
4: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection. Ideal for safeguarding electrical and other high value equipment. Offers unlimited use of sanitary facilities in case of backflow. Is easily serviced. Can be installed in a building’s storm water drains. Is not sensitive to sand and solid objects in the water.
Lifting stations
5: What are the disadvantages of the traditional gravitation system?
Many gravitation pipes with a small diameter have to be installed outside the building and the inspection wells are expensive
You can find the answer here >
5: What are the disadvantages of the traditional gravitation system?
Inspection wells are difficult to maintain and the initial cost of the pumping pit is high
You can find the answer here >
5: What are the disadvantages of the traditional gravitation system?
Many gravitation pipes have to be installed outside the building and a great deal of excavation work is needed.
6: Why is the life cycle cost of the pressurised wastewater system low?
There are only a few gravitation pipes outside the building and the excavation cost is low
You can find the answer here >
6: Why is the life cycle cost of the pressurised wastewater system low?
The initial cost of the lifting station is lower compared with a pit and there are no gravitation pipes outside the building
6: Why is the life cycle cost of the pressurised wastewater system low?
The lifting station and the pipe system is maintenance-free
You can find the answer here >
7: Who has the financial responsibility in the case of flooding in most countries?
The building owner and the building designers
7: Who has the financial responsibility in the case of flooding in most countries?
The government and the wastewater authorities
You can find the answer here >
7: Who has the financial responsibility in the case of flooding in most countries?
The building designers and the contractors
You can find the answer here >
8: What are the four most common types of wastewater from commercial buildings?
Wastewater, storm water, drainage water and wastewater from parking areas
8: What are the four most common types of wastewater from commercial buildings?
Rainwater, wastewater, storm water and drainage water
You can find the answer here >
8: What are the four most common types of wastewater from commercial buildings?
Wastewater, storm water, air-conditioning wastewater and wastewater from parking areas
You can find the answer here >